Acudor · Fire-Rated Access Doors
FB-5060
Quote requiredFire-Rated UnInsulated Access Door
The Acudor FB-5060 is an uninsulated, fire-rated, metal access door for walls.
- Door / Door Frame
- Steel or Stainless Steel: 16 gauge door, 16 gauge mounting frame. Flush to frame with reinforced edges, flange to be 1" wide
- Hinge
- Concealed
- Fire Rating (Walls)
- UL — 1-1/2 hour "B" label. ULC — 2 hour "B" label. (optional). Max sizes 36 x 48 and 24” x 79”
- Standard Compliances
- UL 10B; CAN/ULC S104; NFPA 80
- Standard Latch
- Universal self-latching bolt, operated by either a knurled knob or flush key. When master keying is required, doors can be prepared for rim or mortise cylinder locks.
- Finish
- Baked White Prime Coat (Additional finish paint is recommended for superior corrosion resistance)
Description, photography, drawings and documents as published by Acudor. Their product page ↗
Standard Sizes
17 sizes. Every figure is Acudor's published data.| Nominal Door Size W&H · Inches | Nominal Door Size W&H · mm | Latches | Weight per Door · lbs. | Weight per Door · kg. | |
|---|---|---|---|---|---|
| 8 X 8 | 203 X 203 | 1 | 5.5 | 2.5 | |
| 10 X 10 | 254 X 254 | 1 | 6.5 | 2.9 | |
| 12 X 12 | 305 X 305 | 1 | 8.2 | 3.7 | |
| 14 X 14 | 356 X 356 | 1 | 8.3 | 3.8 | |
| 16 X 16 | 406 X 406 | 1 | 11.1 | 5.0 | |
| 18 X 18 | 457 X 457 | 1 | 13.8 | 6.3 | |
| 20 X 20 | 508 X 508 | 2 | 18.0 | 8.2 | |
| 22 X 22 | 559 X 559 | 2 | 21.0 | 11.3 | |
| 22 X 30 | 559 X 762 | 2 | 24.9 | 12.5 | |
| 22 X 36 | 559 X 914 | 2 | 27.5 | 12.5 | |
| 24 X 24 | 610 X 610 | 1 | 20.1 | 9.1 | |
| 24 X 30 | 610 X 762 | 2 | 25.6 | 11.6 | |
| 24 X 36 | 610 X 914 | 2 | 29.7 | 13.5 | |
| 24 X 48 | 610 X 1219 | 2 | 35.7 | 16.2 | |
| 30 X 30 | 762 X 762 | 2 | 28.4 | 12.9 | |
| 36 X 36 | 914 X 914 | 2 | 38.7 | 17.6 | |
| 36 X 48 | 914 X 1220 | 2 | 48.8 | 22.1 |
- Other sizes available upon request
- Wall opening is nominal door size + 3/8” ( 9 mm) For detailed specifications see submittal sheet
Acudor builds other sizes to order — the table is their standard range, not their limit. Tell the desk the opening you have and we'll quote the door for it.
Product Highlights
- Designed to maintain continuity in a 2 hour fire rated wall, when temperature rise is not a factor
- UL 1-1/2 hour "B" label. ULC 2 hour "B" label. (optional)
- Inside latch release
- Self-closing & self-latching door mechanism
Documents
5 documents, served straight from Acudor so you always get the current revision.
Ask About This Product
Answered from Acudor's own documents — the 2 sheets listed above — with the source and page behind every line.