Hanger Wire is available in 8, 9 and 12 gauge

ClarkDietrich · Specialty Clips & Connectors

Hanger Wire & Tie Wire

Quote required

Available by 50 lbs. hanks (bundles).

Hanger Wire is available in 8 and 12 gauge and is galvanized for corrosion resistance. Hanger wire is suspended from the underside of the floor structure to provide a structural support for drop, gypsum wallboard or plaster suspended ceilings. Tie Wire is 18-gauge galvanized soft annealed wire used in drywall and plaster construction to tie furring channels to main runner U-channels. It’s also used to tie metal lath to channels in plaster construction, attach expansion/control joints to lath and tie the lath overlap between rows of fasteners. 18ga tie wire is not recommended for suspension. In a drop ceiling assembly U-Channel is suspended from the overhead structure using hanger wire. Drywall furring channel is wire-tied perpendicular to the underside of the U-Channel at appropriate intervals for screw-attaching drywall. Assemblies are installed per the project specification or ASTM C 754 requirements. Wire ties are required for fire-rated and multilayer assemblies.

Description, photography, tables and documents as published by ClarkDietrich. Their product page ↗

Product Data & Ordering Information

3 codes. Every figure is ClarkDietrich's published data.
Product codeGaugeDiameterLengthFeet per lb.Wt./Ctn.Submittal
HW880.162"12'14.350 lbsPDF ↗
HW12120.1055"12'33.750 lbsPDF ↗
TW18180.047"30"166.225 lbsPDF ↗

Codes are what ClarkDietrich publishes as available, not a promise of local stock — tell the desk the connection you have and we'll confirm what's on a shelf. A code with no sheet of its own can be generated from ClarkDietrich SubmittalPro ↗.

Product Highlights

  • Available by 50 lbs. hanks (bundles).
  • Class 1 coating
  • Tensile range 55,000-65,000 psi.
  • Breaking strength for 12ga soft wire is 375 lbs.Recommend a minimum safety factor of 1/4.Maximum recommended load on each wire is 94 lbs.
  • Recommend a minimum safety factor of 1/4.
  • Maximum recommended load on each wire is 94 lbs.

Documents

Served straight from ClarkDietrich so you always get the current revision. Each code's own submittal sheet is on its row in the table above.

CAD Details

4 details for this connection, each published as a PDF to read and a DWG and DXF to draw with.

Ask About This Product

Answered from ClarkDietrich's own documents — the 2 sheets listed above — with the source and page behind every line.

AI · cites its sources

Answers come from ClarkDietrich's published documents and our own product record, and are generated — check anything you are about to build to against the source we link. Never quotes prices; the page above does that.