ClarkDietrich · Roof & Truss Connections
SwiftClip™ 150 x 150 LS-Series
Quote requiredPre-punched SwiftClips™ are used for multiple construction applications.
Pre-punched SwiftClips™ are used for multiple construction applications. They are commonly used for lateral bracing CRC connections, header & sill connections and floor joist hangers. The L-shaped clips fit between the stud flanges, so that shorter length clips do not need to be ordered. Fixed clips should not be used in place of a deflection clip.
- Material
- Structural Grade 50 Type H (ST50H), 50ksi
- Coating
- G90 (Z275) hot-dipped galvanized coating
Description, photography, tables and documents as published by ClarkDietrich. Their product page ↗
Product Data & Ordering Information
18 codes. Every figure is ClarkDietrich's published data.| Product code | Gauge | Mils | Design thickness (in) | Size (in) | Packaging | Common Application | Submittal | |
|---|---|---|---|---|---|---|---|---|
| LS543 | 16 | 54 | 0.0566 | 1-1/2 x 1-1/2 x 3-1/4 | 300 pieces per bucket | CRC/Openings | PDF ↗ | |
| LS683 | 14 | 68 | 0.0713 | 1-1/2 x 1-1/2 x 3-1/4 | 300 pieces per bucket | Openings | PDF ↗ | |
| LS973 | 12 | 97 | 0.1017 | 1-1/2 x 1-1/2 x 3-1/4 | 200 pieces per bucket | Openings | PDF ↗ | |
| LS545 | 16 | 54 | 0.0566 | 1-1/2 x 1-1/2 x 5-1/2 | 200 pieces per bucket | CRC/Openings/Joists | PDF ↗ | |
| LS685 | 14 | 68 | 0.0713 | 1-1/2 x 1-1/2 x 5-1/2 | 200 pieces per bucket | Openings/Joists | PDF ↗ | |
| LS975 | 12 | 97 | 0.1017 | 1-1/2 x 1-1/2 x 5-1/2 | 100 pieces per bucket | Openings/Joists | PDF ↗ | |
| LS547 | 16 | 54 | 0.0566 | 1-1/2 x 1-1/2 x 7-1/4 | 150 pieces per bucket | CRC/Openings/Joists | PDF ↗ | |
| LS687 | 14 | 68 | 0.0713 | 1-1/2 x 1-1/2 x 7-1/4 | 100 pieces per bucket | Openings/Joists | PDF ↗ | |
| LS977 | 12 | 97 | 0.1017 | 1-1/2 x 1-1/2 x 7-1/4 | 100 pieces per bucket | Openings/Joists | PDF ↗ | |
| LS549 | 16 | 54 | 0.0566 | 1-1/2 x 1-1/2 x 9-1/4 | 100 pieces per bucket | Joists | PDF ↗ | |
| LS689 | 14 | 68 | 0.0713 | 1-1/2 x 1-1/2 x 9-1/4 | 100 pieces per bucket | Joists | PDF ↗ | |
| LS979 | 12 | 97 | 0.1017 | 1-1/2 x 1-1/2 x 9-1/4 | 50 pieces per bucket | Joists | PDF ↗ | |
| LS541 | 16 | 54 | 0.0566 | 1-1/2 x 1-1/2 x 11-1/4 | 100 pieces per bucket | Joists | PDF ↗ | |
| LS681 | 14 | 68 | 0.0713 | 1-1/2 x 1-1/2 x 11-1/4 | 50 pieces per bucket | Joists | PDF ↗ | |
| LS971 | 12 | 97 | 0.1017 | 1-1/2 x 1-1/2 x 11-1/4 | 50 pieces per bucket | Joists | PDF ↗ | |
| LS5413 | 16 | 54 | 0.0566 | 1-1/2 x 1-1/2 x 13-1/4 | 50 pieces per bucket | Joists | PDF ↗ | |
| LS6813 | 14 | 68 | 0.0713 | 1-1/2 x 1-1/2 x 13-1/4 | 50 pieces per bucket | Joists | PDF ↗ | |
| LS9713 | 12 | 97 | 0.1017 | 1-1/2 x 1-1/2 x 13-1/4 | 25 pieces per bucket | Joists | PDF ↗ |
Codes are what ClarkDietrich publishes as available, not a promise of local stock — tell the desk the connection you have and we'll confirm what's on a shelf. A code with no sheet of its own can be generated from ClarkDietrich SubmittalPro ↗.
Installation
INSTALLATION SwiftClip Support Clips are attached to the cold-formed steel (CFS) framing members using #10 minimum self-drilling screws driven through the clip holes into the steel framing. Connections to the building frame can be made with powder-actuated fasteners, drill-in concrete anchors or welding. It is the responsibility of the design engineer to detail the attachment of clips and verify their capacity meets the application. Place the first two screws in each leg in the outermost screw holes. Place the next two screws (if needed) in center holes next to the CRC holes (diagonal). The next screws (if needed) are placed moving from the outermost holes toward the center, symmetrically.
ClarkDietrich Suggests Instead
Connectors they list as alternatives for this connection.
- FastBridge™ Clip
- SwiftClip™ 1-1/2" x 3" (LE-Series)
- SwiftClip™ 3" x 3" (LA-Series)
- EasyClip™ Support & End Clips
Documents
Served straight from ClarkDietrich so you always get the current revision. Each code's own submittal sheet is on its row in the table above.
- BIMBIM / Revit
- SustainabilityPROSustainability
- Swift-Clip™ L-Series™ Catalog PageCatalog page
- IAPMO ER-0731Document
- AISI S100-16 (2020) w/S2-20Code report
- SDS For ASTM A1003 Steel Framing ProductsSafety data sheet
- AIA / CEUDocument
- CAD Details LibraryCAD detail
- Clip Express Product CatalogCatalog page
- Architectural SpecsSpecification
- CAD DetailsCAD detail
CAD Details
61 details for this connection, each published as a PDF to read and a DWG and DXF to draw with.
- Back-to-Back Header Web StiffenerPDFDWGDXF
- Base Connection To I-Beam With LS-Series ClipPDFDWGDXF
- Base Connection To Metal Deck With LS-Series ClipPDFDWGDXF
- Base Connection To Slab With LS-Series ClipPDFDWGDXF
- Base Connection Swift LS To Steel ChannelPDFDWGDXF
- Block and Strap BridgingPDFDWGDXF
- BoxHeader Connection Detail 1PDFDWGDXF
- BoxHeader Connection Detail 2PDFDWGDXF
- BoxHeader Connection Detail 3PDFDWGDXF
- BoxHeader Connection Detail 4PDFDWGDXF
- BoxHeader Connection Detail 7PDFDWGDXF
- FastBridge Lateral Bracing 2 0PDFDWGDXF
- Furring Wall ConnectionPDFDWGDXF
- Int. Joist Bearin-StandardPDFDWGDXF
- Joist Bridging-Solid BlockingPDFDWGDXF
- Joist Bridging-StrongbackPDFDWGDXF
- Joist Bridging-TDSB Metal Deck 0PDFDWGDXF
- Joist Bridging-Tension StrapPDFDWGDXF
- Joist Bridging-U ChannelPDFDWGDXF
- Joist Lap-Single to Double JoistsPDFDWGDXF
- Joist Lap-StandardPDFDWGDXF
- Kicker Connection to Bottom of Bar Joist 1PDFDWGDXF
- Kicker Connection to Bottom of Beam 1PDFDWGDXF
- Kicker Connection to Bottom of Deck 1PDFDWGDXF
- Kicker Connection to Bottom of Slab 3PDFDWGDXF
- Kicker Connection to Top of Deck 1PDFDWGDXF
- Kicker Connection to Top of Deck 2PDFDWGDXF
- Kicker Connection to Top of Deck 3PDFDWGDXF
- Ladder Blocking-Capped Rim Double JoistPDFDWGDXF
- Ladder Blocking-Double JoistPDFDWGDXF
- Ladder Blocking-Single Joist RimPDFDWGDXF
- Ladder Blocking-StandardPDFDWGDXF
- Ladder Blocking-Standard w out TDSBPDFDWGDXF
- Lay-In Header Connection 1PDFDWGDXF
- Lay-In Header Connection 2PDFDWGDXF
- Lay-In Header Connection 3PDFDWGDXF
- Lay-In Header Connection 4PDFDWGDXF
- RedHeaderPro Lateral Connection 0PDFDWGDXF
- RedHeaderPro LayinSill ConnectionPDFDWGDXF
- RedHeaderPro SillTrack ConnectionPDFDWGDXF
- Sill Detail 3PDFDWGDXF
- Sill Detail 4PDFDWGDXF
- Sill Detail 5PDFDWGDXF
- Sill Detail 6PDFDWGDXF
- Sill Detail 7PDFDWGDXF
- Solid Blocking Detail 2PDFDWGDXF
- Spazzer 5400PDFDWGDXF
- Stud Connection LS-Series Clip Bottom Of BeamPDFDWGDXF
- Stud Connection LS-Series Clip To Angle%26TrackPDFDWGDXF
- Stud Connection LS-Series Clip To AnglePDFDWGDXF
- Stud Connection LS-Series Clip To CMUPDFDWGDXF
- Stud Connection LS-Series Clip To ConcretePDFDWGDXF
- Stud Connection %282%29LS-Series ClipsPDFDWGDXF
- Stud Connection LS-Series ClipPDFDWGDXF
- Stud Framed Suspended CeilingPDFDWGDXF
- Support Clip ClarkDietrich S SeriesPDFDWGDXF
- SwiftClip-ChartPDFDWGDXF
- Track Head Connection 1PDFDWGDXF
- Track Head Connection 3PDFDWGDXF
- U Channel Bridging ConnectionPDFDWGDXF
- U Channel DetailPDFDWGDXF