walls.one
MaxTrak deflection track head-of-wall detail

Interior & exterior · per stud width

View on ClarkDietrich ↗

ClarkDietrich

11 sizes in stock

MaxTrak® Slotted Deflection Track

MaxTrak® Slotted Deflection Track and MaxTrak 2D Slotted Deflection & Drift Track let the top of a stud float within the track legs, absorbing primary-structure live-load movement without transferring axial load into the wall studs. MaxTrak 2D adds web slots for horizontal seismic drift.

Gauge / mil

30 mil

Yield

33 ksi (structural, 30mil–43mil range) — confirm by leg/gauge combination

Coating

CP60 / G40EQ depending on structural vs. non-structural line

  • Rolled to match the stud width it caps — order it in the same web size as your wall stud
  • 2-1/2" leg MaxTrak: 1-1/2" long slots, total allowable vertical deflection 1-1/2" (3/4"±)
  • 3" leg MaxTrak: 2" long slots, total allowable vertical deflection 2" (1"±)
  • MaxTrak 2D adds up to 4" total allowable horizontal drift movement (2"±)
  • Non-structural MaxTrak comes in the 2-1/2" leg only; structural comes in 2-1/2" and 3"
  • One-piece system — no additional deflection clips or components to install
  • MaxTrak 2-1/2" leg system carries Intertek code report CCRR-0205
  • Integrates with UL® head-of-wall fire-stop systems; UL Designs 2079 Fifth Edition
Head-of-Wall ConnectionChase WallFire-Rated SystemsExterior Curtain Wall

Worth knowing before you specify

MaxTrak is ordered by leg height and structural / non-structural line rather than by a per-width member code — ClarkDietrich publishes one submittal sheet per configuration, covering every stud width it is rolled for. Pick your wall's web width in the order panel.

Members

6 of 6 members. Every figure is ClarkDietrich's published data.

Member #VariantSizeFlangeGaugeMilKsiCoating
MaxTrak-STRMaxTrak 2-1/2" Leg — Structuralper stud width2-1/2"structural30 milCP60Submittal ↗
MaxTrak-3inLeg-STRMaxTrak 3" Leg — Structuralper stud width3"structural30 milCP60Submittal ↗
MaxTrak2D-STRMaxTrak 2D 2-1/2" Leg — Structuralper stud width2-1/2"structural30 milCP60Submittal ↗
MaxTrak2D-3inLeg-STRMaxTrak 2D 3" Leg — Structuralper stud width3"structural30 milCP60Submittal ↗
MaxTrak-DWMaxTrak 2-1/2" Leg — Non-Structural (Drywall)per stud width2-1/2"20 ga EQ30 milG40EQSubmittal ↗
MaxTrak2D-DWMaxTrak 2D 2-1/2" Leg — Non-Structural (Drywall)per stud width2-1/2"20 ga EQ30 milG40EQSubmittal ↗

Specifications

As published by ClarkDietrich.

Material
Slotted U-track — Structural and Non-Structural (drywall) MaxTrak and MaxTrak 2D
Yield strength
33 ksi (structural, 30mil–43mil range) — confirm by leg/gauge combination
Coating
CP60 / G40EQ depending on structural vs. non-structural line
Design standard
AISI S100, S220, S240
Code approvals
Intertek CCRR-0205 · UL Designs 2079 (5th Ed.) · UL File XHLI.R26034 (types SLT, SLT-H)
Fire rated
Integrates with UL head-of-wall fire-stop systems
Sizes
per stud width
Gauge / mil
30 mil

Documents

12 documents, served straight from ClarkDietrich and its testing agencies so you always get the current revision.

Ask About This Product

Answered from ClarkDietrich's own documents — the 8 sheets listed above — with the source and page behind every line.

AI · cites its sources