Studs in 100 ft of wall
Length over spacing, plus one. No openings or corners.
- 12″ on centre101 studs
- 16″ on centre76 studs
- 24″ on centre51 studs
Material calculators
Estimate a small job room by room: drywall sheets, joint compound, tape, screws, metal studs, track and ceiling tile for every room and for the whole job. Add the answer to a material list with the other calculators, then price the list in your order.
1 · EnterThe sizes off the plans
2 · SeeThe count, and how it was worked out
3 · AddEach answer to one material list
4 · SendThe list to your order or a submittal
Wall length, height and spacing in. Studs, track, deflection track, screws and fasteners out.
All runs added together
9'6 or 9.5 both work
Cold-rolled channel through the studs
Openings, corners and ends
You need about
48studs at 9′
98 LF of track · about 188 lb of steel
Drywall stud, 3-5/8" 25 ga EQ, 9′
37 at 16″ o.c. + 8 for openings, corners and ends, 5% waste
48pcs151 lb
Track, 3-5/8" 25 ga EQ, 10′
98 LF: floor and head, 8 LF over and under openings, 5% waste
11pcs36 lb
Framing screws, 7/16″ pan head
4 at each stud, 8 more at each opening
208screws
Track fasteners, pins or anchors
Floor and head track at 24″ o.c. Match the fastener to the slab and the deck.
Pick the pin or anchor for your substrate. The catalog does not list how many come in a box.
49pcs
These start at the figures our own takeoffs use. Your changes are kept in this browser and used by every calculator.
Wall and ceiling area in. Sheets out, and the same wall compared in 8, 10 and 12 foot board.
All walls added together
Openings
You need about
18sheets, 4′ × 12′
780 SF of board to hang · about 1,901 lb
Type X Drywall, 4′ × 12′
780 SF of board after 84 SF of openings, 10% waste, 48 SF a sheet
18sheets1,901 lb
One face of a 48′ wall, hung with the long edge level. Butt ends have no taper, so every butt joint is slower to finish flat. The heavy lines are butt joints.
8 ft sheets
9 ft sheets
10 ft sheets
12 ft sheets
Fewest butt jointsA 12 ft sheet of 5/8″ board is a two-person carry. Check the stairs, the corridor and the elevator before you have it stocked.
These start at the figures our own takeoffs use. Your changes are kept in this browser and used by every calculator.
Board area and finish level in. Joint compound, tape, screws, corner bead and sealant out.
Bead, trim and sealant
Length of wall, not of bead
You need about
4boxes of compound
370 LF of tape · 1,125 screws · Level 4
Paper joint tape, 500′ roll
370 LF at 0.37 LF per SF of board
1rolls
All-purpose joint compound, 3.5 gal box
Tape and bed coat, 1 box per 850 SF, with 40 LF of bead and trim
2boxes100 lb
Lightweight topping compound, 3.5 gal box
Two finish coats for Level 4, 1 box per 700 SF for two coats
2boxes64 lb
Drywall screws, 1-1/4″ fine thread
1.13 per SF on framing 16″ o.c., about 4 lb
The catalog does not list how many are in a box. 5,000 assumed for 1-1/4″.
1,125screws4 lb
Corner bead, 10′
40 LF of outside corner, 10% waste
5pcs
These start at the figures our own takeoffs use. Your changes are kept in this browser and used by every calculator.
Room sizes in. Main runners, cross tees, wall angle, hanger wire and panels out.
You need about
1062 × 2 panels
384 SF of ceiling in 1 room
Ceiling panels, 2′ × 2′
384 SF with 10% waste. Pick a panel to see cartons.
106panels
15/16″ main runner, 12′
Mains 4′ apart, running the length of each room
7pcs
15/16″ cross tee, 4′
Between the mains, 2′ apart
49pcs
15/16″ cross tee, 2′
Splits each 2′ × 4′ opening for a 2′ × 2′ panel
53pcs
Wall angle, 12′
Around the walls of each room
8pcs
Hanger wire, 12 ga
One every 4′ along each main. Seismic bracing and fixtures need more.
The catalog does not list how many wires are in a bundle. 100 assumed.
18wires
Ordering a ceiling? The ceiling grid builder puts these parts in your order with our item numbers, and the guide walks through the count by hand.
These start at the figures our own takeoffs use. Your changes are kept in this browser and used by every calculator.
Room size in. Drywall grid or channel and furring, hanger wire, board and screws out.
You need about
7sheets, 4′ × 12′
280 SF of ceiling · 3 lines of carrying channel · about 842 lb
Cold-rolled channel, 1-1/2″, 16′
3 lines of carrying channel 4′ apart, 60 LF
4pcs31 lb
Furring channel, 7/8″, 12′
16 runs at 16″ o.c. across the channel, 224 LF
20pcs72 lb
Furring clips or tie wire
One where each furring channel crosses a carrying channel
Clips or tie wire are not matched to the catalog. Add them as a note.
48ties
Hanger wire, 12 ga
One every 4′ along each carrier
The catalog does not list how many wires are in a bundle. 100 assumed.
18wires
Type X Drywall, 4′ × 12′
280 SF of ceiling, 10% waste
7sheets739 lb
Drywall screws, 1-1/4″ fine thread
1.13 per SF on framing 16″ o.c.
The catalog does not list how many are in a box. 5,000 assumed for 1-1/4″.
315screws
These start at the figures our own takeoffs use. Your changes are kept in this browser and used by every calculator.
Wall length and height in. Square feet of cavity and bags of batts out.
Insulated walls only
Above a ceiling, a soffit, a shaft
Read it off the bag you are buying
You need about
7bags
390 SF of cavity to fill
Mineral wool batt, 3" for studs 16" o.c.
390 SF of cavity, 5% waste, 59.7 SF a bag
Bag coverage is not in the catalog. Check it against the bag you are buying.
7bags
These start at the figures our own takeoffs use. Your changes are kept in this browser and used by every calculator.
Your cut list in. Sticks to buy and scrap left over, for each stock length.
One line for each length: a mark, the length, how many. A1, 9'6, 24 or 24 @ 9'6 or pasted from a spreadsheet.
You need about
37sticks of 20′
71 LF of scrap, 10% of what you buy
Stock lengths to cut from, 20′
68 pieces, 669 LF used and 71 LF of scrap (10%)
This counts sticks only. Pick the stud or track and its size in your order.
37pcs
and 27 more sticks cut the same way
Or skip the saw. We cut studs and track to length.
Order each length on this list as its own line and it arrives cut and bundled by mark. That is the 71 LF of scrap above that never reaches the job.
Order cut to lengthThese start at the figures our own takeoffs use. Your changes are kept in this browser and used by every calculator.
A row for each room in. Board, finishing, framing and ceiling for the whole job out.
Meant for a small job or a quick check. Each room counts the board on its own side of its walls, so list the corridor as a room to pick up its side. Studs are counted at the tallest room's height.
You need about
56sheets, 4′ × 12′
2,422 SF of board · 202 studs · 1,304 SF of acoustical ceiling
Drywall stud, 3-5/8" 25 ga EQ, 10′
148 at 16″ o.c. + 44 for openings, corners and ends, 5% waste
202pcs707 lb
Track, 3-5/8" 25 ga EQ, 10′
405 LF: floor and head, 30 LF over and under openings, 5% waste
43pcs142 lb
Framing screws, 7/16″ pan head
4 at each stud, 8 more at each opening
856screws
Type X Drywall, 4′ × 12′
2,422 SF of board, 10% waste, 48 SF a sheet
56sheets5,914 lb
Paper joint tape, 500′ roll
896 LF at 0.37 LF per SF of board
2rolls
All-purpose joint compound, 3.5 gal box
Tape and bed coat, 1 box per 850 SF
3boxes150 lb
Lightweight topping compound, 3.5 gal box
Two finish coats for Level 4, 1 box per 700 SF for two coats
4boxes128 lb
Drywall screws, 1-1/4″ fine thread
1.13 per SF on framing 16″ o.c., about 10 lb
The catalog does not list how many are in a box. 5,000 assumed for 1-1/4″.
2,725screws9 lb
Ceiling panels, 2′ × 2′
1,304 SF with 10% waste. Pick a panel to see cartons.
359panels
15/16″ main runner, 12′
Mains 4′ apart, running the length of each room
27pcs
15/16″ cross tee, 4′
Between the mains, 2′ apart
174pcs
15/16″ cross tee, 2′
Splits each 2′ × 4′ opening for a 2′ × 2′ panel
188pcs
Wall angle, 12′
Around the walls of each room
23pcs
Hanger wire, 12 ga
One every 4′ along each main. Seismic bracing and fixtures need more.
The catalog does not list how many wires are in a bundle. 100 assumed.
68wires
| Room | Length | Width | Height | Doors | Windows | Ceiling | Shared walls | Sheets | |
|---|---|---|---|---|---|---|---|---|---|
| 29 | |||||||||
| 12 | |||||||||
| 9 | |||||||||
| 7 |
Board by room
These start at the figures our own takeoffs use. Your changes are kept in this browser and used by every calculator.
Estimates, worked from the sizes you enter and the rules shown under each calculator. Check them against the drawings before you order. Rated and structural walls are built to the tested assembly and the engineer's design, not to a rule of thumb.
Reference
A count is a size multiplied by a rule. These are the rules and the weights the calculators start from. The weights are the manufacturers' published figures for what we sell.
Length over spacing, plus one. No openings or corners.
Pounds per foot, by gauge. ClarkDietrich ProSTUD.
Pounds, by board. CertainTeed published weights.
| Material | The rule we start from | For 1,000 SF of board |
|---|---|---|
| Joint tape | 0.37 LF for each SF of board | 370 LF, one 500′ roll |
| All-purpose compound, taping coat | 1 box (3.5 gal) covers 850 SF | 1.2 boxes |
| Topping compound, two finish coats | 1 box (3.5 gal) covers 700 SF | 1.4 boxes |
| Drywall screws, framing 24″ o.c. | 0.75 for each SF | 750 screws, about 2.5 lb |
| Drywall screws, framing 16″ o.c. | 1.13 for each SF | 1125 screws, about 3.8 lb |
| Level 5 primer-surfacer | 1 gallon covers 110 SF | 10 gallons |
| Board waste | 10% | 23 sheets of 4 × 12 |
After the count
The list opens matched to our catalog with the sizes you chose. Change a quantity or a brand, then request a quote or place the order.
Back to the listThe same products go to the submittal builder, which binds each manufacturer's data sheet into one PDF with your part numbers marked.
Open the submittal builderFor a full set of drawings, upload the bid documents. We measure every wall and ceiling and send back the takeoff, an Excel bid sheet and a quote.
See the AI takeoff serviceQuestions
The rules behind each calculator, in a sentence or two.
Divide the wall length in inches by the stud spacing and add one. A 48 ft wall at 16 inches on centre is 37 studs. Then add two for each door or window, two for each corner and one for each free end, and about 5% for waste. The metal studs calculator does this and adds the track.
Multiply the wall length by the height, and by two if both sides get board. Take out about 21 square feet for a door and 15 for a window, add 10% for waste, and divide by the area of one sheet: 32 square feet for a 4 × 8, 48 for a 4 × 12.
For a Level 4 finish we figure one 3.5 gallon box of all-purpose compound for every 850 square feet of board for the taping coat, one box of topping compound for every 700 square feet for the two finish coats, and 370 feet of tape for every 1,000 square feet. You can change each figure to your own.
Main runners run the length of the room, 4 ft apart. Four-foot cross tees go between them every 2 ft. A 2 × 2 ceiling adds a 2 ft cross tee in each opening. Wall angle goes around the room, and a hanger wire carries each main every 4 ft. Enter the room size and the ceiling calculator counts each part.
They are the figures we use for our own takeoffs: 10% waste on board, 5% on framing and insulation, 10% on ceilings and trim. Each calculator shows the rules it used under its result, and every one of them can be changed. Your changes are kept in your browser.
Yes. Add each answer to the material list, then press Price it in your order. The list opens matched to our catalog with the sizes you chose. Items with a list price are priced straight away and the rest go to our desk for a number. Nothing is ordered until you check out.
They are estimates from simple rules, good for a small job, a change order or a check on somebody else's count. For a bid on a full set of plans, use the AI takeoff service: it measures every wall and ceiling on the drawings.
They count material. They do not design a wall. A fire-rated or sound-rated wall is built to its tested assembly, and a structural or exterior wall to the engineer's design, so take the stud size, gauge and spacing from those and use the calculator for the quantities.