Metal framing
How to Read a Metal Stud Part Number
Updated
Short answer
A metal stud part number reads web depth, shape, flange width, then thickness. 362S162-33 is a 3-5/8 inch web (362), stud (S), 1-5/8 inch flange (162), 33 mil steel. Depths and flanges are in hundredths of an inch and thickness is in mils.
The Four Parts of the Number
| Part | In the example | Means |
|---|---|---|
| Web depth | 362 | 3-5/8" — the depth of the member, in hundredths of an inch |
| Shape | S | Stud or joist: a C shape with stiffening lips |
| Flange width | 162 | 1-5/8" — the width of the flange, in hundredths of an inch |
| Thickness | 33 | 33 mil — the minimum steel thickness in thousandths of an inch |
Hundredths are cut off, not rounded. 3-5/8" is 3.625", which is written 362, never 363. That member in the catalog is 362S162-33-P.
Shape Letters: S, T, U and F
| Letter | Shape | Example |
|---|---|---|
| S | Stud or joist — C shape with lips | 600S162-54-P |
| T | Track — U shape with no lips, the stud sits inside it | 362T125-33 |
| U | Cold-rolled channel — small U used for bridging and ceiling carrying channel | 150U050-54 |
| F | Furring channel — hat shape | 087F125-18 |
On track, the first number is the stud size it fits and the second is the leg height. 362T125-33 is track for 3-5/8" studs with 1-1/4" legs. Deep-leg and slotted deflection track have 2" to 3" legs.
Common Web and Flange Codes
| Code | Depth |
|---|---|
| 162 | 1-5/8" |
| 250 | 2-1/2" |
| 350 | 3-1/2" |
| 362 | 3-5/8" |
| 400 | 4" |
| 550 | 5-1/2" |
| 600 | 6" |
| 800 | 8" |
| 1000 | 10" |
| 1200 | 12" |
| Code | Width | Usually |
|---|---|---|
| 125 | 1-1/4" | Drywall studs and standard track |
| 137 | 1-3/8" | Structural studs |
| 162 | 1-5/8" | Structural studs |
| 200 | 2" | Structural studs and joists, deep-leg track |
| 250 | 2-1/2" | Joists, deep-leg track |
| 300 | 3" | Joists, deep-leg track |
The thickness codes are 15, 18, 30, 33, 43, 54, 68 and 97. The metal stud gauge chart converts each one to gauge and inches.
ClarkDietrich Letters You Will See
Manufacturers replace the S or T with their own letters on proprietary products. The numbers around them read the same way.
| Letters | Product | Example |
|---|---|---|
| PDS | ProSTUD drywall stud | 362PDS125-18 |
| PDT | ProTRAK drywall track | 362PDT125-18 |
| TLE | TRAKLOC elevator stud | 250TLE125-24 |
| ZG | Z-girt for rainscreen framing | 150ZG-43 |
More Examples
| Part number | Reads as |
|---|---|
| 250PDS125-15 | 2-1/2" ProSTUD drywall stud, 1-1/4" flange, 15 mil (25 ga EQ) |
| 362PDS125-30 | 3-5/8" ProSTUD drywall stud, 1-1/4" flange, 30 mil (20 ga drywall) |
| 600S162-43-P | 6" structural stud, 1-5/8" flange, 43 mil (18 ga) |
| 800S200-54-P | 8" structural stud, 2" flange, 54 mil (16 ga) |
| 087F125-30 | 7/8" furring channel, 30 mil |
Common Questions
- What does 362S162-33 mean?
- It is a 3-5/8 inch deep stud with a 1-5/8 inch flange in 33 mil steel. 362 is the web depth in hundredths of an inch, S means stud, 162 is the flange width in hundredths of an inch and 33 is the thickness in mils.
- What does the S mean in a metal stud size?
- S means a stud or joist section, a C shape with stiffening lips. T means track, U means cold-rolled channel and F means furring channel.
- What does 600S162-54 mean?
- It is a 6 inch deep stud with a 1-5/8 inch flange in 54 mil (16 gauge) steel.
- Why is a 3-5/8 inch stud written 362 and not 363?
- The depth is written in hundredths of an inch with the rest cut off, not rounded. 3-5/8 inch is 3.625 inch, which becomes 362.
- What does PDS mean on a ClarkDietrich stud?
- PDS is ClarkDietrich's code for a ProSTUD drywall stud. 362PDS125-18 is a 3-5/8 inch ProSTUD with a 1-1/4 inch flange in 18 mil steel, sold as 20 gauge EQ. PDT is the matching ProTRAK track.
Order it
Stock lengths or cut to your exact size, priced before you send the order. Not sure what the job takes? Send the plans and we will send back a material list.
Sources
- ClarkDietrich Product Identification
- AISI S200 series, North American Standards for Cold-Formed Steel Framing
Figures are the manufacturers’ published values and the catalog’s own data. The project drawings, specifications and the engineer of record govern what a job requires.