Acudor · Roof Hatches & Smoke Vents
RHATB Thermally Broken Roof Hatch
Quote requiredRHATB Thermally Broken Roof Hatch Aluminum
Acudor RHATB Thermally Broken Roof Hatches are designed to provide superior energy efficiency together with convenient, economical access to the roof of a building
- Cover
- Double-skin construction (“in box type design”) with 3” Polyiso (R-18) insulation integrating non-conductive separator between exposed exterior and interior surfaces, providing superior thermal performance and improved energy efficiency. EPDM foam weather draft seal gasket on the inside of the cover assures weather tight construction. The cover is 11Ga Aluminum with a 20Ga aluminum inside liner, with thicknesses adjusted to suit sizes.
- Curb
- 11Ga Aluminum with 3” thick Polyiso (R-18) insulation integrating non-conductive separator between exposed exterior and interior surfaces, providing superior thermal performance and improved energy efficiency. Curb is 12” high.
- Thermal Performance
- Tested to ASTM C1363-11 (Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus)
- Hinge
- Heavy duty Aluminum pintle hinges with 3/8" SS pin
- Opening
- Gas spring operators allow cover to open and close with ease. Stainless Steel Inside pull handle allows for easy control when closing cover.
- Latch
- Self latching, Stainless steel outside T handle with stainless steel inside lock and lever assembly. Unit also has inside padlock provisions.
- Finish
- Mill finish.
Description, photography, drawings and documents as published by Acudor. Their product page ↗
RHATB Standard Sizes
8 sizes. Every figure is Acudor's published data.| Model | Curb ID W&L · inches (mm) | Weight per Hatch · lbs. (kg.) | |
|---|---|---|---|
| RHA2424T | 24 x 24 (610 x 610) | 60 (27.3) | |
| RHA2436T | 24 X 36 (610 X 914) | 70 (31.8) | |
| RHA3030T | 30 x 30 (762 x 762) | 77 (34.0) | |
| RHA3036T | 30 x 36 (762 x 914) | 84 (38.6) | |
| RHA3636T | 36 x 36 (914 x 914) | 91 (43.2) | |
| RHA3054T | 30 x 54 (762 x 1372) | 105 (47.6) | |
| RHA3096T | 30 x 96 (762 x 2438) | 165 (75.0) | |
| RHA4848T | 48 x 48 (1219 x 1219) | 122 (55.0) |
- (other sizes available)
- For detailed specifications see submittal sheet
Acudor builds other sizes to order — the table is their standard range, not their limit. Tell the desk the opening you have and we'll quote the door for it.
Product Highlights
- Thermally broken design
- 3” Polyiso (R-18) insulation integrating non-conductive separator between exposed exterior and interior surfaces, providing superior thermal performance and improved energy efficiency.
- Stainless Steel Hardware standard on all hatches
- Tested to ASTM C1363-11 (Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus)
Documents
5 documents, served straight from Acudor so you always get the current revision.
Ask About This Product
Answered from Acudor's own documents — the 2 sheets listed above — with the source and page behind every line.