walls.one
RHATB Thermally Broken Roof Hatch — Aluminum — Acudor

Acudor · Roof Hatches & Smoke Vents

RHATB Thermally Broken Roof Hatch

Quote required

RHATB Thermally Broken Roof Hatch Aluminum

Acudor RHATB Thermally Broken Roof Hatches are designed to provide superior energy efficiency together with convenient, economical access to the roof of a building

Cover
Double-skin construction (“in box type design”) with 3” Polyiso (R-18) insulation integrating non-conductive separator between exposed exterior and interior surfaces, providing superior thermal performance and improved energy efficiency. EPDM foam weather draft seal gasket on the inside of the cover assures weather tight construction. The cover is 11Ga Aluminum with a 20Ga aluminum inside liner, with thicknesses adjusted to suit sizes.
Curb
11Ga Aluminum with 3” thick Polyiso (R-18) insulation integrating non-conductive separator between exposed exterior and interior surfaces, providing superior thermal performance and improved energy efficiency. Curb is 12” high.
Thermal Performance
Tested to ASTM C1363-11 (Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus)
Hinge
Heavy duty Aluminum pintle hinges with 3/8" SS pin
Opening
Gas spring operators allow cover to open and close with ease. Stainless Steel Inside pull handle allows for easy control when closing cover.
Latch
Self latching, Stainless steel outside T handle with stainless steel inside lock and lever assembly. Unit also has inside padlock provisions.
Finish
Mill finish.

Description, photography, drawings and documents as published by Acudor. Their product page ↗

RHATB Standard Sizes

8 sizes. Every figure is Acudor's published data.
ModelCurb ID W&L · inches (mm)Weight per Hatch · lbs. (kg.)
RHA2424T24 x 24 (610 x 610)60 (27.3)
RHA2436T24 X 36 (610 X 914)70 (31.8)
RHA3030T30 x 30 (762 x 762)77 (34.0)
RHA3036T30 x 36 (762 x 914)84 (38.6)
RHA3636T36 x 36 (914 x 914)91 (43.2)
RHA3054T30 x 54 (762 x 1372)105 (47.6)
RHA3096T30 x 96 (762 x 2438)165 (75.0)
RHA4848T48 x 48 (1219 x 1219)122 (55.0)
  • (other sizes available)
  • For detailed specifications see submittal sheet

Acudor builds other sizes to order — the table is their standard range, not their limit. Tell the desk the opening you have and we'll quote the door for it.

Product Highlights

  • Thermally broken design
  • 3” Polyiso (R-18) insulation integrating non-conductive separator between exposed exterior and interior surfaces, providing superior thermal performance and improved energy efficiency.
  • Stainless Steel Hardware standard on all hatches
  • Tested to ASTM C1363-11 (Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus)