ClarkDietrich · Backing Connections
FastBack® Backing System (FBBC)
Quote requiredHandrails
Perfect backing system for: D-Blaze® and FlamePRO® FRT is pressure-treated wood that is chemically treated to reduce the flamespread and smoke development. Both D-Blaze® and FlamePRO® are Class A fire retardant; EPA registered, and comply with all national codes including the International Building Code (IBC) and the International Residential Code (IRC). FastBack® - U.S. Patent Nos. 7,882,676 is owned by Jeffery Thomas Ellis
- Thickness
- 3/4" (5 ply)
Description, photography, tables and documents as published by ClarkDietrich. Their product page ↗
Product Data & Ordering Information
11 codes. Every figure is ClarkDietrich's published data.| Product code | Packaging | Stud Flange Width | Height | Backing Thickness | Width | For Stud Spacing | Submittal | |
|---|---|---|---|---|---|---|---|---|
| FBBC5 | 50 pieces per carton | 1-1/4" | 5-1/8" | 3/4" (5 ply) | — | — | PDF ↗ | |
| FBBC10 | 50 pieces per carton | 1-1/4" | 10-1/4" | 3/4" (5 ply) | — | — | PDF ↗ | |
| FBBC5-2X | 50 pieces per carton | 1-1/4" | 5-1/8" | 1-1/2" (2X Lumber) | — | — | PDF ↗ | |
| 162-FBBC5-2X | 50 pieces per carton | 1-5/8" | 5-1/8" | 1-1/2" (2X Lumber) | — | — | PDF ↗ | |
| 200-FBBC5-2X | 50 pieces per carton | 2" | 5-1/8" | 1-1/2" (2X Lumber) | — | — | PDF ↗ | |
| 5FBW12 | 720 pieces per skid | — | 10-1/2" | — | 5-1/8" | 12"o.c. | — | |
| 5FBW16 | 540 pieces per skid | — | 14-1/2" | — | 5-1/8" | 16"o.c. | — | |
| 5FBW24 | 360 pieces per skid | — | 22-1/2" | — | 5-1/8" | 24"o.c. | — | |
| 10FBW12 | 720 pieces per skid | — | 10-1/2" | — | 10-1/4" | 12"o.c. | — | |
| 10FBW16 | 540 pieces per skid | — | 14-1/2" | — | 10-1/4" | 16"o.c. | — | |
| 10FBW24 | 360 pieces per skid | — | 22-1/2" | — | 10-1/4" | 24"o.c. | — |
Codes are what ClarkDietrich publishes as available, not a promise of local stock — tell the desk the connection you have and we'll confirm what's on a shelf. A code with no sheet of its own can be generated from ClarkDietrich SubmittalPro ↗.
Product Highlights
- Handrails
- Baseboards
- Door Jams and Wood Trim
- Cabinets and Vanities
- The system creates an interlocked design between the stud and track for baseboard backing installations; and a cutaway design allows backing and bracing to be installed all the way to the floor. Optional pre-cut and fire-retardant D-Blaze® or FlamePRO® Wood Backing is sized to fit 12," 16" and 24" o.c. spacing and can be used with the FBBC5 or FBBC10 clip. Available for overnight delivery.
- FBBC5-2X, 162-FBBC5-2X and 200-FBBC5-2X are designed to support traditional 2X lumber.
- D-Blaze® is a registered trademark of Viance, LLC.
- FlamePRO® is a registered trademark of Koppers Performance Chemicals, Inc.
- Clip Material: Grade 50ksi min. yield strength, G90
- 33mils: 20ga STR, 0.0346”Design Thickness, 0.0329“ Min. Thickness
Installation
Rotate the FastBack® clip over the flange of the stud until it sits flush. Fasten into place using (3) #8 wafer head/pan head screws to metal stud at each pre-punched hole. Place wood onto tabs and fasten into place using three #8 wafer head/pan head screws. One screw placed at the center and one screw placed 1/2" from top and bottom edges of wood.
Documents
Served straight from ClarkDietrich so you always get the current revision. Each code's own submittal sheet is on its row in the table above.
CAD Details
1 detail for this connection, each published as a PDF to read and a DWG and DXF to draw with.
Ask About This Product
Answered from ClarkDietrich's own documents — the 3 sheets listed above — with the source and page behind every line.